| Screening |
Protects pumps and downstream equipment from large debris. |
Bars or perforated screens physically intercept leaves, sticks, plastics, and other coarse materials. |
Opening size commonly ranges from about 6 to 75 mm, depending on the screen type and source-water conditions. |
Rags, branches, leaves, plastics, and other large debris. |
Removal of visible coarse solids before chemical treatment. |
| Coagulation |
Destabilizes small suspended and colloidal particles that do not settle readily. |
A coagulant is rapidly mixed into the water. The chemical reduces electrical repulsion between particles and promotes the formation of small chemical precipitates. |
Rapid-mix contact commonly lasts about 10 to 60 seconds, with a mixing intensity of approximately 300 to 1,000 s-1. Chemical dose and pH are determined by jar testing and raw-water quality. |
Colloids, fine clay, organic particles, microorganisms attached to solids, and some color-causing matter. |
Stable formation of pin floc and improved particle aggregation in the next stage. |
| Flocculation |
Grows small destabilized particles into larger, heavier flocs. |
Slow, controlled stirring increases contact between particles while minimizing floc breakage. Polymer aids may be used when appropriate. |
Typical detention time is about 15 to 45 minutes, with a lower mixing intensity of approximately 20 to 80 s-1. Many systems use tapered mixing, from faster to slower agitation. |
Aggregated suspended solids, precipitated metals, organic matter, and particles captured by the growing floc. |
Visible, settleable flocs that remain intact during transfer to the sedimentation basin. |
| Sedimentation |
Separates flocculated solids from the water by gravity. |
Water flows slowly through a basin. Flocs settle to the bottom as sludge, while clarified water moves toward collection launders or outlets. |
Conventional basins often provide about 1.5 to 4 hours of detention time. Surface overflow rates commonly fall near 20 to 50 m3/m2·day, subject to design and water quality. |
Settleable floc, suspended solids, precipitated compounds, and a portion of particle-associated microorganisms. |
Well-operated clarification can commonly remove about 80% to 99% of suspended solids, although actual results depend on raw-water quality and process control. |
| Sludge Collection and Removal |
Prevents settled solids from being resuspended and removes concentrated residuals. |
Scrapers, hoppers, pumps, or suction systems collect sludge from the basin floor for thickening, dewatering, treatment, or permitted disposal. |
Sludge withdrawal frequency is set according to solids loading, basin geometry, and sludge concentration rather than a single universal value. |
Concentrated floc, chemical precipitates, organic solids, and retained suspended matter. |
Stable sludge blanket or clear basin floor without excessive solids carryover. |
| Filtration |
Removes fine particles that remain after sedimentation. |
Water passes through granular media or membranes. Remaining particles are captured by straining, interception, adsorption, and attachment to the filter media. |
Rapid granular filters commonly operate at approximately 5 to 15 m/h, depending on media, design, and treated-water requirements. |
Fine floc, residual turbidity, algae, and some microorganisms. |
Filtered-water turbidity is often targeted below 0.3 NTU in conventional drinking-water treatment, subject to applicable regulations. |
| Disinfection |
Inactivates disease-causing microorganisms before distribution. |
Chemical disinfectants or ultraviolet light damage or disable bacteria, viruses, and protozoa. Chemical systems may maintain a protective residual in the distribution network. |
Required contact time and disinfectant concentration depend on temperature, pH, organism type, and regulatory targets. |
Pathogenic bacteria, viruses, and protozoa that remain after physical treatment. |
Measured inactivation credits, disinfectant residual, and microbiological compliance. |